- Stock: In Stock
- Model: ST22011823
- Dimensions: 65.00mm x 96.00mm x 48.00mm
- SKU: ST22011823
Available Options
Features:
- Accurate measurement
- Easy operation
- High precision
- Settable current ratio
- Strong anti-interference
- Widely used in electronic measurement, industrial automation control.
- There is a high-quality fixing frame to prevent loosening and long-term fixation.
Specification:
Display range | DF3 four digits -1999~ +3300 |
Sampling times | 2~128 times/second (s), factory setting 4 times/second (s) |
Measurement accuracy | DF3-D: soil 0.5% F.S ±2Digit |
Display | Red LED (14.2mm H) |
Frequency range | 45Hz~60Hz(max) |
Polarity display | positive and negative reading display |
Weight | about 350g |
Power supply | AC110V/AC220V. 50/60Hz (other power supply methods can be selected) |
Power consumption | about 3VA (220VAC 50Hz) |
Temperature and humidity resistance | 0~50°C 35%~85% RH |
Withstand voltage | AC2KV, 1 minute between power/input/output |
Size | W96 x H48 x D65mm |
Installation | plate type |
DF3-D DC Ammeter
Current | Resolution | Test Range |
DC300.0uA | 0.1uA | -200.0uA---+300.0uA |
DC3.000MA | 0.001MA | -2.000MA---+3.000MA |
DC30.00MA | 0.001MA | -20.00MA---+30.00MA |
DC300.0MA | 0.1MA | -200.0MA—+300.0MA |
DC3000MA | 1MA | -2000MA---+3000MA |
DC5.00A | 0.01A | -2.000---+3.000A |
DC3.000A | 0.001A | -2.000A—+3.000A |
DC5.00A | 0.01A | -5.00A—+5.00A |
DC10.00A | 0.01A | -10.00A---+10.00A |
Note: If it is greater than DC10A, a shunt test is required, and the shunt is separately equipped.
Change set value:
- Enter: Press the ⟲ key for 3 seconds, the meter will enter the function setting menu mode.
- Change: Press ︽ or ︾ to enter the next setting item. Press the key to move the cursor to the left and the digits will flash cyclically.
- Press ︽ or ︾ again to modify the value of the flashing digit. After modifying, press ⟲ to confirm and save.
- Exit: When the setting is completed, press ⟲3 seconds to exit, and the instrument saves the changed setting parameters.
- If no button is operated for 30 seconds, the meter will automatically exit the parameter setting mode.
- The modified parameters will be saved.
Package included:
- 1 x DC Ammeter
Note:
[1] Please do not use in the following environments: places where temperature and humidity changes too much; places where vibration is very strong, places where corrosive oxygen or dust exists; places where water, oil, and chemicals splash; easy to explode and flammable gas.
[2] Before connecting the power supply, please make sure whether the voltage is within the rated range and whether the wiring terminals are positive Yes, otherwise it may cause serious damage to the instrument.
[3] The input wire should not be too long, it is better to use shielded wire.
[4] Keep the wiring junction away from high-voltage, high-current power supply lines to avoid interference, please confirm that the wiring is connected to the correct terminal.
[5] Before use, the meter needs to be energized and preheated for 15 minutes; the suitable use environment temperature is 0~50°C.
[6] Please note that the shell of the body will be corroded by organic solvents, strong acids and alkalis.
[7] It is strictly forbidden to disassemble, modify and repair this product, otherwise it will not be guaranteed.
Details pictures: