Menu
Your Cart

T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour

T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay T2310 Normally Open Timer Control Module 0-999S/Min/Hour
  • Stock: In Stock
  • Model: ST230048262
  • Dimensions: 67.00mm x 45.00mm x 34.00mm
  • SKU: ST230048262
$6.99
Ex Tax: $6.99

Available Options

Feature:

Independent crystal oscillator, more accurate timing
1. Convenient direct output wiring
2. Add buzzer and audible alarm
3. Add p1ause button to stop urgently
5. Start and stop setting mode, provincial conversion, which is more convenient
6. Automatically save when power off, run automatically when power on
7. Timing units can be set separately, with 36 working combinations
8. Timing range: 0-999 seconds, minutes, hours
9. To count in minutes or hours, the digital tube flashes in seconds.
Note: This product is a countdown operation and cannot be set to a 24-hour working mode.

Specifications:

Controller typeNormally open time controller
Operating VoltageDC12VDC24VAC110~220V
Control circuit voltageDC12VDC24VAC110~220V
Relay carrying power240W480W10A(max)
Recommended power<Relay carrying power×80%
Relay typeNormally open relay
Power consumption<1W
Relay service life100000 Times
Timing error±3s(in 24 hours)
Weight65g
Size67mm×45mm ×34mm
Fixed wayEmbedded Hole 63mm×42mm

Operation Introduction:

1. In the conventional interface, long press the SET button for 10 seconds to enter the setting mode, the red digital tube displays the code, and the green digital tube displays the code parameter value; press the SET key to switch the code, and press the up/down keys to modify the parameter value.
2. Adjust the value of P0 and P1 to 0 (time unit is second)
3. Adjust P2 to 5, the relay is closed first and then opened, and continuously circulates
4. Wait for 10 seconds to automatically save the settings after the code setting is completed
5. To set the timing time, double-click the SET button on the conventional interface, the red digital tube flashes, press the up/down keys to adjust the value to 10, click the SET button, the green digital tube flashes, adjust the value to 50, wait for 10 seconds to automatically save, set carry out.
All settings are automatically saved when power is turned off and run automatically when power is turned on, without manual start.
Press and hold the SET key to power on to restore the factory settings.

Package Included:

 1 x T2310 Programmable Digital Time Delay

T2310-DC-12V-24V-AC-110V-220V-Programmable-Digital-Time-Delay-Switch-Relay-T2310-Normally-Open-Timer-1776609-1

T2310-DC-12V-24V-AC-110V-220V-Programmable-Digital-Time-Delay-Switch-Relay-T2310-Normally-Open-Timer-1776609-2

T2310-DC-12V-24V-AC-110V-220V-Programmable-Digital-Time-Delay-Switch-Relay-T2310-Normally-Open-Timer-1776609-3

T2310-DC-12V-24V-AC-110V-220V-Programmable-Digital-Time-Delay-Switch-Relay-T2310-Normally-Open-Timer-1776609-4

T2310-DC-12V-24V-AC-110V-220V-Programmable-Digital-Time-Delay-Switch-Relay-T2310-Normally-Open-Timer-1776609-5


Write a review

Note: HTML is not translated!
Bad Good
Captcha